Sensor natural gamma radiation

Sensor natural gamma radiation

Intended USE

  • linking in a geological section
  • lithological division of the section
  • calculation of the clay content coefficient

FEATURES AND BENEFITS

  • high-precision scintillation sensor with NaI crystal
  • reinforced construction with increased vibration resistance and reliability
  • high sensor sensitivity

APPLICATIONS IN DOWNHOLE EQUIPMENT

  • downhole telemetry system
  • Nadolny module
  • rotary-controlled system

Technical Specifications

Input voltage

20÷30V

Input current

8÷20mA, 8mA at 28V

The output signal

5V negative pulse

X-and Y-axis impact resistance

1000g / 0.5 MS 1/2 sinusoidal signal

The resistance in the Z-axis

500g / 0.5 MS 1/2 sinusoidal signal

Vibration resistance (on 3 axes)

30÷200 Hz, 20g

Operating temperature

0÷175°C

Model range

Diameter

Length

Measuring range

Accuracy

Sensitivity

19.0 mm

349.0 mm

1000API

5%

1.0 Imp / sec / API

26.7 mm

422.5 mm

1000API

5%

1.9 Imp / sec / API

34.5 mm

340.0 mm

1000API

5%

2.2 Imp / sec / API